12kV Switchgear, Panel, Switchboard/MV switchgear/MV switchgear/Hight voltage switchgear/HV switchboard/Vacuum switchgear
12kV Switchgear, Panel, Switchboard/MV switchgear/MV switchgear/Hight voltage switchgear/HV switchboard/Vacuum switchgear
Product Details

12kV Switchgear/Panel/Switchboard/MV switchgear/MV switchgear/Hight voltage switchgear/HV switchboard/Vacuum switchgear

Joyelectric International is a professional manufacturer, supplier and distributor of 12kv switchgear in China, welcome to order 12kv switchgear products from our factory and company.

KYN28-12(Z) Indoor HV Vacuum Switchgear

Main charateristics

The enclosure is made of aluminum-zinc coated sheet processed by bending several times.

All operations should be done under the door closed.

The high protection degree can avoid ingression of substance or insects enter.

Wrong operation can be avoided due to its simple and effective "Five Prevention".

It can equipped with ZN63A and VD4 type vacuum circuit breakers.

For the truck has good interchangeability, it is easy to change vacuum circuit breakers.

For saving space, the switchgear can be installed against wall and maintained from the front side.

There are enough place for connection cables.

Instant earthing switch can be used for eathing operation and short circuiting operation.

It can be separated equipped with heater inside the VCB compartment and cable compartment to prevent condensation and erosion.

It conforms to GB3906.DL404-1997 and refers to IEC-298 standard.

Applying ambient conditions

Ambient temperature: The max. temperature should below +40, the min .temperature should above -15.

The height above sea level should be no higher than 1000m.

The earthquake intensity should be no more than 8 degree.

Relative humidity: The average humidity of a day should be no more than 95%.The average humidity of a month should be no more than 90%.

Water vapour pressure: The average vapour pressure of a day should be more than 2.2kPa. The average vapour pressure of a month should be no more than 1.8kPa.

It should be used in the place where it is free from fire, explosion, serious fifth, chemical erosion and vibration.

The main technical specification of the cubical switchboard            

No.

Name

Unit

Data

1

Rated voltage

kV

3.6  7.2  12

2

Rated current

A

630  1250  1600  2000  2500  3150  4000

3

Rated frequency

Hz

50

4

Rated short time withstand current

kA

16  20  25  31.5  40  50

5

Rated peak withstand current

40  50  63  80  100  125

6

Rated power frequency withstand voltage

Pole to pole,

pole to earth

kV

42/1min

Across nterrupter

48/1min

7

Rated lightning impulse withstand voltage

Pole to pole,

pole to earth

75

Across nterrupter

85

8

Rated short-time duration

S

4

9

Degree of Protection


IP4X

Main technical specification of vacuum breaker                            

No.

Name

Unit

Data

1

Rated voltage

kV

3.6  7.2  12

2

Rated current

A

630 1250 1600 2000 2500 3150 4000

3

Rated short circuit breaking current

kA

16 20 25 31.5 40 50

4

Rated short-time withstand current

16 20 25 31.5 40 50

5

Rated peak withstand current

40 50 63 80 100 125

6

Rated power frequency withstand voltage

Pole-to-pole,

Pole-to-earth

kV

42/1min

Across nterrupter

48/1min

7

Rated lightning impulse withstand voltage

Pole-to-pole,

Pole-to-earth

75

Across nterrupter

85

8

Rated short-time duration

S

4

9

Opening time

ms

20t65

10

Closing time

ms

20t75

11

Breaking operations of rated short circuit- breaking current

Cycle

30(31.5kA)

20(40kA)

12

Mechanical endurance

Cycle

20000(31.5kA)  10000(40kA)

Main technical specification of spring operation mechanism                   

Name

Unit

Data

Rated operating voltage

Opening coil

V

DC220/110  AC220/110

Closing coil

Power of coil

Opening coil

W or VA

245

Closing coil

Power of energy-stored motor

W

50

Rated voltage of energy-stored motor

V

DC220/110  AC220/110

Charging time

S

10

Structure

 

Overall dimension and base mounting drawing

 mm

Height

2350

Width

Rated current of small branch bus-bar is 1250A and the below shrt-circuit breakingcurrent is 31.5KA

800

Rated current of small branch bus-bar is 1600A and above

1000

Depth

  Cale In-(out)

1500

  Overhead In-(out)

1660

Weight(kg)               800~1200

                                                                                                                                            mm

Width

Depth

M

N

L

800

1500 cable

630

800

1450

1660 overhead

1610

1000

1500 cable

830

1000

1450

1660 overhead

1610

 